GFP1-IP65 Waterproof Plastic Distribution Box
● Standard: IEC/EN 62208:2023, IEC 60529,IEC 62262:2021,IEC 60695-2-10:2013
● lP65 degree of protection
● Lock structure
● Reserved position for functional stickers
● Reserved for installation of anti-theft locks
● With knockout hole
● With copper terminal assemblies
● The specifications include :4, 6, 9, 13, 15, 18, 26, 36 and 39 ways
GFP1M Single Phase Metal Consumer Units
● Standard:BS EN/IEC 61439-3
● Number of digits (No.):4,5,6,10,14,18,24,28,36
● Rated currentln (A):63A,100A,125A
● Rated voltage: 230/240V~ 50/60Hz
● Way to install:Wall mounting,Earth and neutral terminal bars at the top
● Material Thickness:1.0mm Steel,RAL 9001 powder-coated finish
● Ambient air temperature: -35℃~+70℃
GFU1-Ⅰ+Ⅱ AC Surge Protective Device
● Core applications:Lightning protection and surge protection for incoming line cabinets.
● Certification:IEC 61643-11.
● Kind of test:Type1+2/ClassⅠ+Ⅱ
● Number of poles:1:1P,2:2P,3:3P,4:4P,1PN:1P+NPE,3PN:3P+NPE
● Dash current:7:7kA,12:12.5kA
● Maximum continuous operating voltage(N-PE)(Uc):255V
● Working voltage:150:150V;275:275V;320:320V;385:385V;440:440V
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
GFU1Z-Ⅰ+Ⅱ DC Surge Protective Device
● Certification:IEC 61643-31.
● Kind of test:Type1+2/ClassⅠ+Ⅱ
● Number of poles:2:2P,3:3P
● Maximum continuous operating voltage (Uc):2P(1000VDC),3P(1500VDC)
● Nominal discharge current (8/20μs) (In):20kA
● Maximum discharge current (8/20μs) (Imax):50kA
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
GFU1-Ⅱ AC Surge Protective Device
● Core applications:Lightning protection and surge protection for incoming line cabinets.
● Certification:IEC 61643-11.
● Kind of test:Type2/ClassⅡ
● Number of poles:1:1P,2:2P,3:3P,4:4P,1PN:1P+NPE,3PN:3P+NPE
● Dash current:7:7kA,12:12.5kA
● Maximum continuous operating voltage(N-PE)(Uc):255V
● Working voltage:150:150V;275:275V;320:320V;385:385V;440:440V
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
GFU1Z-Ⅱ DC Surge Protective Device
● Certification:IEC 61643-31.
● Kind of test:Type2/ClassⅡ
● Number of poles:2:2P,3:3P
● Maximum continuous operating voltage (Uc):2P(1000VDC),3P(1500VDC)
● Nominal discharge current (8/20μs) (In):20kA
● Maximum discharge current (8/20μs) (Imax):40kA
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
● Standard: IEC/EN60669-2-2
● Number of poles:1,2P
● (Ue) 1P,2P Rated voltage of main circuit (Ue):1R 2P 24V-250 V AC
● Dissipated power(within pulse duration):19 VA
● Button control with indicator light:30mA
● Boundary dimension(mm):86x72x18
● Contact load(resistive):GFC1-25:25A 250VAC
● Electrical life(Times):1x10²
● Mechanical life(Times):2x10²
GFC1-25 Household AC Contactor
● Standard: IEC/EN/BS EN 61095
● Rated current: 16A,20A,25A,32A,40A,63A
● Number of poles: 1P(1NO、1NC),2P(2NO、2NC、1NO1NC),3P(3NO、3NC),4P(4NO、4NC、2NO2NC、3NO1NC)
● Rated power supply voltage Us(V):AC24V AC230V
● Intermitlent working systen:30 times/h load factor 40%
● Certificates: CB, CE, UKCA,SEMKO
GFB1L-40AFD AFDD RCBO Arc Fault Protection Circuit Breaker
● Series:GFB1L-40AFD
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
GFB1L-40AFDH AFDD RCBO Arc Fault Protection Circuit Breaker
● Series:GFB1L-40AFDH
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
Product Categories
No data
Product Categories
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
Whatsapp:+86-19511298526
No.136-138,Xinguang Avenue,Xinguang lndustrial
Zone,Liushi,Yueqing,Wenzhou,Zhejiang,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.