GFB1L-40AFD AFDD RCBO Arc Fault Protection Circuit Breaker

GFB1L-40AFD Devices are a single module device which fits the existing busbar system of the existing arrangement. The device offers protection against overcurrent, short circuit, earth leakage and arc fault all in one device and are available in B&C Curve variants. It can direct replacement RCBO in existing consumer units.Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A.
● Series:GFB1L-40AFD
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V 
● max. Operating voltage range of test circuit:253V 
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO

View more →

GFB1L-40AFDH AFDD RCBO Arc Fault Protection Circuit Breaker

GFB1L-40AFDH Devices are a single module device which fits the existing busbar system of the existing arrangement. The device offers protection against overcurrent, short circuit, earth leakage and arc fault all in one device and are available in B&C Curve variants. It can direct replacement RCBO in existing consumer units.Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A.
● Series:GFB1L-40AFDH
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V 
● max. Operating voltage range of test circuit:253V 
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO

View more →

< 1 > proceed page

Sales support

Yueqing Good Future Electrical Co.,Ltd.

Phone: +86  138  0686  5401 

Tel: +86  577  6161  6165 

Email : gf@gf-ele.com

No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town

Yueqing City,Wenzhou City,Zhejiang Province,China

 

Certificate

图片名称
图片名称

Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.

安安新材料

Business license

Get in touch

Provide comprehensive technical support and maintenance services to respond to your needs in a timely manner.