AFDD RCBO Arc Fault Protection Circuit Breaker
undefined
GFB1L-40AFD AFDD RCBO Arc Fault Protection Circuit Breaker
GFB1L-40AFD Devices are a single module device which fits the existing busbar system of the existing arrangement. The device offers protection against overcurrent, short circuit, earth leakage and arc fault all in one device and are available in B&C Curve variants. It can direct replacement RCBO in existing consumer units.Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A.
● Series:GFB1L-40AFD
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
● Series:GFB1L-40AFD
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
GFB1L-40AFDH AFDD RCBO Arc Fault Protection Circuit Breaker
GFB1L-40AFDH Devices are a single module device which fits the existing busbar system of the existing arrangement. The device offers protection against overcurrent, short circuit, earth leakage and arc fault all in one device and are available in B&C Curve variants. It can direct replacement RCBO in existing consumer units.Residual current operated circuit-breaker with integral overcurrent protection as Fire protection switch,sensitive to pulsating and alternating currents Type A.
● Series:GFB1L-40AFDH
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
● Series:GFB1L-40AFDH
● Standard: IEC/EN 61009-1, IEC 62026
● Type of RCBO: AC, A
● Rated current: 6A, 10A, 16A, 20A, 25A, 32A, 40A
● Rated voltage: 230/240V~
● Rated impulse withstand voltage: 4kV
● min. Operating voltage range of test circuit:196V
● max. Operating voltage range of test circuit:253V
● Operating frequency:50/60Hz
● Number of poles: 1P+N (with switched neutral)
● Rated Residual Operating Current ( I∆n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -35 ºC-+70 ºC
● Connection: From bottom
● Certificates: CB,CE, UKCA, SEMKO
Product Categories
No data
Product Categories
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town
Yueqing City,Wenzhou City,Zhejiang Province,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.