Miniature Circuit Breaker
-
GFB1-63 Miniature Circuit Breaker
-
GFB1-63H Miniature Circuit Breaker
-
GFB1-125 Plastic case circuit breaker
-
GFB1-125H Plastic case circuit breaker
-
GFB1-40N Plastic case circuit breaker
-
GFB1-40NH Plastic case circuit breaker
-
GFB1-63Z DC circuit breaker
-
GFB1-63ZH DC circuit breaker
-
GFB1-63ZG DC circuit breaker
-
GFB1-63ZGH DC circuit breaker
-
GFB1-125Z DC circuit breaker
-
GFB1-125ZH DC circuit breaker
-
GFB1-125ZG DC circuit breaker
-
GFB1-125ZGH DC circuit breaker
-
-
Switch Disconnector
-
GFH1-125 Switch Disconnector
-
GFH1-125H Switch Disconnector
-
GFH1-125B Switch Disconnector
-
GFH1-100 Switch Disconnector
-
GFH1-100D Switch Disconnector
-
GFH1-40X Switch Disconnector
-
GFH1-80X Switch Disconnector
-
GFH1-125X Switch Disconnector
-
GFH1-250 Switch Disconnector
-
GFH1-125Z Changeover Switch
-
GFH1-80F Switch Disconnector
-
GFH1-M324P Switch Disconnector
-
-
Electromagnetic Residual Current Operated Circuit Breaker
-
Electronic Residual Current Circuit Breaker
-
AFDD RCBO Arc Fault Protection Circuit Breaker
-
Household AC Contactor
-
Impulse Relays
-
Surge Protective Device
-
Distribution Box
-
GFB1-40NH Plastic case circuit breaker
GFB1-40NH is a compact RCBO for modern electrical systems, supporting 230/240V and up to 40A. It protects against overcurrent, short circuits, and earth leakages, with advanced DC residual current detection for EV chargers, solar PVs, and heat pumps. Rated 10kA bidirectional, and compliant with IEC/EN standards, it ensures reliable performance.
● Standard: IEC/EN/BS EN60898-1
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~40A
● Rated voltage: 230V
● Number of poles: 1P+N
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -25℃~+40℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
Product Description
●Model and Meaning ●Introduction
GFB1-40NH household circuit breakers are designed for 50Hz AC power lines with rated voltages up to 230V and rated currents up to 40A. They provide overload and short-circuit protection while maintaining normal electrical connections during routine operations.
Compliant with standard: IEC/EN 60898-1, obtained CB,CE UKCA,SEMKOand other certifications.
●Main Parameters and Technical Performance
Technical parameters project | Parameter values |
Rated voltage (V) | 230V |
Rated current (A) | 1A、2A、3A、4A、5A、6A、10A、16A、20A、 25A、32A、 40A |
Number of poles | 1P+N |
Instantaneous trip type | B Mode(3-5)In,C Mode(5-10)In |
Rated breaking capacity (A) | 10kA(GFB1-40NH) |
Energy class | 3 |
Tightening torque (N·m) | 1.5 |
Class of pollution | Level 2 |
levels of protection | IP20 |
Mechanical life and operation frequency (times/hour) | 20000、 240(In≤32A) |
Electrical lifeand operation frequency | 4000、120(In>32A) |
●Connecting lead
Rated current In (A) | Nominal cross-sectional area S (mm²) of copper wire |
1、2、3、4、6、10 | 1-2.5 |
16 | 2.5-4 |
20、25 | 4-6 |
32 | 6-10 |
40 | 10-16 |
●Product Types Choosing
| Rated Current | B curve | C curve |
| 1A | GFB1-40NH B1 | GFB1-40NH C1 |
| 2A | GFB1-40NH B2 | GFB1-40NH C2 |
| 3A | GFB1-40NH B3 | GFB1-40NH C3 |
| 4A | GFB1-40NH B4 | GFB1-40NH C4 |
| 5A | GFB1-40NH B5 | GFB1-40NH C5 |
| 6A | GFB1-40NH B6 | GFB1-40NH C6 |
| 10A | GFB1-40NH B10 | GFB1-40NH C10 |
| 16A | GFB1-40NH B16 | GFB1-40NH C16 |
| 20A | GFB1-40NH B20 | GFB1-40NH C20 |
| 25A | GFB1-40NH B25 | GFB1-40NH C25 |
| 32A | GFB1-40NH B32 | GFB1-40NH C32 |
| 40A | GFB1-40NH B40 | GFB1-40NH C40 |
●Appearance and Installation Dimensions ●Characteristic Curves


Keywords:
Related Products
undefined
Welcome your message consultation
You can also submit information online, and we will reply to you within 24 hours!
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town
Yueqing City,Wenzhou City,Zhejiang Province,China