GFB1L-40L Electromagnetic Residual Current Operated Circuit Breaker(RCBO)
● Standard: IEC/EN 61009-1
● Type: AC, A
● Rated current: 6A,10A,16A,20A,25A,32A,40A
● Rated voltage: 230/240V~
● Number of poles: 1P+N
● Rated Residual Operating Current (IΔn): 10mA,30mA,100mA,300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35℃~+70 ºC
● Connection: From top and bottom
● Certificates: CB,CE,UKCA, SEMKO
GFB1L-40LH Electromagnetic Residual Current Operated Circuit Breaker(RCBO)
● Standard: IEC/EN 61009-1
● Type: AC, A
● Rated current: 6A,10A,16A,20A,25A,32A,40A
● Rated voltage: 230/240V~
● Number of poles: 1P+N
● Rated Residual Operating Current (IΔn): 10mA,30mA,100mA,300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B, C
● Ambient air temperature: -35℃~+70 ºC
● Connection: From top and bottom
● Certificates: CB,CE,UKCA, SEMKO
GFL1-63 Electromagnetic residual current operated circuit breaker(RCCB)
● Standard: IEC/BS EN61008-1, IEC62423,IEC62955
● Residual current type :AC、A、B、EV、F、S
● Rated current: 6A~63A
● Rated voltage: 230/400,400/415V
● Poles: 2P(1P+N), 4P(3P+N), N Pole on left
● Rated sensitivity IΔn: 10mA,30mA, 100 mA, 300mA, 500mA
● Tripping current threshold: 0.4IΔn or 10mA (whichever is greater)
● Ambient air temperature: -25ºC~+40ºC
● Incoming method: Bidirectional
● Certificates: CB, CE, UKCA,SEMKO
GFL1-63H Electromagnetic residual current operated circuit breaker(RCCB)
● Standard: IEC/BS EN61008-1, IEC62423,IEC62955
● Residual current type :AC、A、B、EV、F、S
● Rated current: 6A~63A
● Rated voltage: 230/400,400/415V
● Poles: 2P(1P+N), 4P(3P+N), N Pole on left
● Rated sensitivity IΔn: 10mA,30mA, 100 mA, 300mA, 500mA
● Tripping current threshold: 0.4IΔn or 10mA (whichever is greater)
● Ambient air temperature: -25ºC~+40ºC
● Incoming method: Bidirectional
● Certificates: CB, CE, UKCA,SEMKO
GFL1-100 Electromagnetic Residual Current Operated Circuit Breaker(RCCB)
● Standard: ( A、AC、S)IEC/EN 61008-1, (F)IEC/EN 62423,(EV)IEC/EN 62955
● Type: AC、A、EV、F、S
● Rated current: 63A、80A、100A
● Rated voltage: 230/400V~240/415V
● Poles: 2P(1P+N), 4P(3P+N), N Pole on left
● Rated Residual Operating Current (IΔn): 10mA,30mA,100mA,300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Ambient air temperature: -35...+70 ºC
● Connection: From top and bottom
● Certificates: CB,CE,UKCA, SEMKO
GFL1-100H Electromagnetic Residual Current Operated Circuit Breaker(RCCB)
● Standard: ( A、AC、S)IEC/EN 61008-1, (F)IEC/EN 62423,(EV)IEC/EN 62955
● Type: AC、A、EV、F、S
● Rated current: 63A、80A、100A
● Rated voltage: 230/400V~240/415V
● Poles: 2P(1P+N), 4P(3P+N), N Pole on left
● Rated Residual Operating Current (IΔn): 10mA,30mA,100mA,300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Ambient air temperature: -35...+70 ºC
● Connection: From top and bottom
● Certificates: CB,CE,UKCA, SEMKO
Product Categories
No data
Product Categories
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town
Yueqing City,Wenzhou City,Zhejiang Province,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.