GFB1L-40N Electronic Residual Current Circuit Breaker (RCBO)

GFB1L-40N Electronic residual current circuit Breaker (RCBO) residual current circuit breaker with overcurrent protection , compact, reliable solution for residual current and overcurrent protection. Ideal for residential and commercial applications, offering enhanced electrical safety and easy installation.
● Standard: IEC61009-1
● Type: AC, A
● Rated current: 6A~40A
● Rated voltage: 230/240V~
● Number of poles: Two Poles
● Rated Residual Operating Current (I△n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B, C
● Ambient air temperature: -35℃~+70 ºC
● Connection: From top and bottom
● Certificates: CB,CE, UKCA,SEMKO

Product Description

Model and Meaning                                       Introduction

GFB1L-40N Products provide protection against earth faults, overloads, short circuits and over-voltage in commercial and domestic installation. The RCBO with both disconnected neutral and phase guarantees its proper actuation against earth leakage faults even when the neutral and phase are wrongly connected the electronic RCBO incorporate a filtering device preventing the risks of unwanted due to transient voltages and transient currents.
● This is RCBO can be wired from the bottom or top.
● Provides protection against earth fault/leakage current and function of isolation.
● High short-circuits current withstand capacity.
● Applicable to terminal and pin/fork type busbar connection.
● Fire resistant plastic parts endure abnormal heating and strong impact.
● Automatically disconnect the circuit when earth fault/leakage current occurs and exceeds the rated sensitivity.
● Rated current can reach up to 40A.
Product complies with standard: IEC/EN 61009-1 

Technical Parameters

Product Model

GFB1L-40N

Product complies with standard

IEC/EN 61009-1

No. of poles

1P+N,1 Module, N line with disconnected

Rated current (In)

6A,10A,16A,20A,25A,32A,40A

Rated sensitivity currents I△n

10mA, 30mA, 100mA, 300mA,500mA

Rated short-circuit breaking capacity

6kA

Energy limiting class

3

Rated voltage (Ue)

240V  AC(50/60Hz)

Rated impulse withstand voltage (1.2/50) Uimp

4kV

Dielectric test voltage at ind.Freq. for 1min

2kV

Protection

Ground fault, Overcurrent and short circuit

Type of trip

Ground fault: Electronic

Overload and short circuit: Thermo-magnetic

Type

AC、A

Residual current off-time under I△n

≤0.1s

Reted residual making and breaking capacity (I△m)

500A(In≤50A)

Thermal release characteristic

(1.13-1.45) x In

Magnetic release characteristic

B:(3-5) x In, C:(5-10) x In

Electrical Life

10000 Cycles

Mechanical Life

20000 Cycles

Contact Position Indicator

Yes, ON (red); OFF (green)

Ambient Temperature

-35℃~+70℃, Maximum Humidity 95%

Datum temperature

30℃

Protection Degree

IP20

Terminal connection type

Cable/Pin-type busbar

Max. terminal size for cable

16mm²

Torque (N·m)

2.5N·m

Installation

Mounting on 35mm DIN rail

Connection

From top and bottom

Product Types Choosing

Rated CurrentRated Residual Operation Current(I△n)Product Number
Type  BType  C
6A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB0610        GFB1L-40NB0630
GFB1L-40NB06100      GFB1L-40NB06300
GFB1L-40NB06500

GFB1L-40NC0610        GFB1L-40NC0630
GFB1L-40NC06100      GFB1L-40NC06300
GFB1L-40NC06500

10A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB1010        GFB1L-40NB1030
GFB1L-40NB10100      GFB1L-40NB10300
GFB1L-40NB10500

GFB1L-40NC1010        GFB1L-40NC1030
GFB1L-40NC10100      GFB1L-40NC10300
GFB1L-40NC10500

16A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB1610        GFB1L-40NB1630
GFB1L-40NB16100      GFB1L-40NB16300
GFB1L-40NB16500

GFB1L-40NC1610        GFB1L-40NC1630
GFB1L-40NC16100      GFB1L-40NC16300
GFB1L-40NC16500

20A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB2010        GFB1L-40NB2030
GFB1L-40NB20100      GFB1L-40NB20300
GFB1L-40NB20500

GFB1L-40NC2010        GFB1L-40NC2030
GFB1L-40NC20100      GFB1L-40NC20300
GFB1L-40NC20500

25A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB2510        GFB1L-40NB2530
GFB1L-40NB25100      GFB1L-40NB25300
GFB1L-40NB25500

GFB1L-40NC2510        GFB1L-40NC2530
GFB1L-40NC25100      GFB1L-40NC25300
GFB1L-40NC25500

32A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB3210        GFB1L-40NB3230
GFB1L-40NB32100      GFB1L-40NB32300
GFB1L-40NB32500

GFB1L-40NC3210        GFB1L-40NC3230
GFB1L-40NC32100      GFB1L-40NC32300
GFB1L-40NC32500

40A10mA、30mA、100mA、300mA、500mA

GFB1L-40NB4010        GFB1L-40NB4030
GFB1L-40NB40100      GFB1L-40NB40300
GFB1L-40NB40500

GFB1L-40NC4010        GFB1L-40NC4030
GFB1L-40NC40100      GFB1L-40NC40300
GFB1L-40NC40500

 

Connecting lead

Rated current In (A)

Nominal cross-sectional area S (mm²) of copper wire

6、10

1-2.5

16

2.5-4

20、25

4-6

32

6-10

40

10-16

Appearance and Installation Dimensions                           Characteristic Curves

 

 

Keywords:

Related Products

undefined

undefined

Welcome your message consultation

You can also submit information online, and we will reply to you within 24 hours!

Sales support

Yueqing Good Future Electrical Co.,Ltd.

Phone: +86  138  0686  5401 

Tel: +86  577  6161  6165 

Email : gf@gf-ele.com

No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town

Yueqing City,Wenzhou City,Zhejiang Province,China

 

Certificate

图片名称
图片名称

Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.

安安新材料

Business license

Get in touch

Provide comprehensive technical support and maintenance services to respond to your needs in a timely manner.