GFB1L-63NH Electronic Residual Current Circuit Breaker (3P+N Longbody) RCBO

GFB1L-63NH Residual Current Breaker RCBO 10kA 3 Pole and Neutral 63A C Curve 30mA Type A (Longbody)sidual Current Breaker RCBO 10kA 3 Pole and Neutral 63A C Curve 30mA Type A (Longbody)
GFB1L-63N Range of residual current devices (RCDs) are a high-performance electrical safety solution designed for commercial, industrial and mining applications. These RCDs offer a high level of selectivity, with sensitives including 10mA, 30mA, 100mA,300mA and500mA, types starting at Type A for general purpose applications through to Type F and B for more complex loads.
● Standard: IEC/EN 61009-1
● Type: AC, A
● Rated current: 6A,10A,16A,20A,25A,32A,40A,50A,63A
● Rated voltage: 400/415V~
● Number of poles: 3P+N
● Rated Residual Operating Current (I△n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 10kA
● Tripping curve: B,C
● Ambient air temperature: -35℃~+70 ºC
● Certificates: CB,CE, UKCA,SEMKO

Product Description

Model and Meaning                             ●Introduction

GFB1L-63NH Electronic residual current trip (3P+N) is a low-voltage protection device that integrates overload, short circuit, and leakage protection. Its core feature is the use of electronic trip technology to achieve accurate leakage detection. The following is the key description:
 

 

 

Ⓐ structural property
● Polarity configuration: 3P+N denotes a three-phase (L1/L2/L3) system with a neutral (N) line. The neutral pole is typically used solely for isolation or leakage detection, without overcurrent protection capability.
● Module design: The standard module is 54mm (3×18mm), with the N pole occupying space but not independently separated.
Ⓑ principle of work and power
● Leakage protection: Detects residual current through a zero-sequence current transformer. When the leakage current exceeds the preset threshold (e.g., 30mA), the electronic tripping mechanism activates.
● Wiring requirements: Strictly follow the left neutral, right live principle. The N line must be connected to the terminal marked N. Otherwise, the protection may fail.
Ⓒ application scenarios-Industrial control systems, electrical installations in commercial buildings, and household circuit protection
● Suitable for three-phase four-wire systems (e.g., 380V power equipment) where neutral line leakage detection is required but no neutral line disconnection is needed.
● Common in industrial control, commercial building distribution boxes, etc.
Ⓓ Selection considerations
● Specify the N-pole function requirements (e.g., whether synchronization and disconnection are required)
● Prioritize products compliant with IEC/EN 61009-1 standards, ensuring a breaking capacity of ≥10kA

Technical Parameters

Product Model

GFB1L-63NH

Product complies with standard

IEC/EN 61009-1

No. of poles

3P+N

Rated current (In)

6A,10A,16A,20A,25A,32A,40A,50A,63A

Rated sensitivity currents I△n

10mA, 30mA, 100mA, 300mA,500mA

Rated short-circuit breaking capacity

10kA

Energy limiting class

3

Rated voltage (Ue)

400/415V  

Rated impulse withstand voltage (1.2/50) Uimp

4kV

Trip curve

B、C

Leakage current type 

AC、A

Tripping time

300ms

Min.service voltage

207V

Max.operating voltage(Uamx)

457V

Protected neutral pole

No

Isolator application

Yes

Disconnection characteristic

Undelayed

Protection

Ground fault, Overcurrent and short circuit

Type of trip

Ground fault: Electronic

Overload and short circuit: Thermo-magnetic

Residual current off-time under I△n

≤0.1s

Reted residual making and breaking capacity (I△m)

500A(In≤50A)

Thermal release characteristic

(1.13-1.45) x In

Magnetic release characteristic

B:(3-5) x In, C:(5-10) x In

Electrical Life

10000 Cycles

Mechanical Life

20000 Cycles

Contact Position Indicator

Yes, ON (red); OFF (green)

Ambient Temperature

-35℃~+70℃, Maximum Humidity 95%

Datum temperature

30℃

Protection Degree

IP20

Connectable conductor cross section solid-core

1-25mm²

Connectable conductor cross section multi-wired

1-16mm²

Torque (N·m)

-35℃~+70℃, Maximum Humidity 95%

Installation

30℃

Depth

IP20

Height

1-25mm²

Width

1-16mm²

Product Types Choosing

Rated CurrentRated Residual Operation Current(I△n)Product Number
Type  BType  C
6A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB0610         GFB1L-63NHB0630
GFB1L-63NHB06100       GFB1L-63NHB06300
GFB1L-63NHB06500

GFB1L-63NHC0610            GFB1L-63NHC0630
GFB1L-63NHC06100          GFB1L-63NHC06300
GFB1L-63NHC06500

10A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB1010         GFB1L-63NHB1030
GFB1L-63NHB10100       GFB1L-63NHB10300
GFB1L-63NHB10500

GFB1L-63NHC1010            GFB1L-63NHC1030
GFB1L-63NHC10100          GFB1L-63NHC10300
GFB1L-63NHC10500

16A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB1610          GFB1L-63NHB1630
GFB1L-63NHB16100        GFB1L-63NHB16300
GFB1L-63NHB16500

GFB1L-63NHC1610            GFB1L-63NHC1630
GFB1L-63NHC16100          GFB1L-63NHC16300
GFB1L-63NHC16500

20A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB2010          GFB1L-63NHB2030
GFB1L-63NHB20100        GFB1L-63NHB20300
GFB1L-63NHB20500

GFB1L-63NHC2010            GFB1L-63NHC2030
GFB1L-63NHC20100          GFB1L-63NHC20300
GFB1L-63NHC20500

25A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB2510          GFB1L-63NHB2530
GFB1L-63NHB25100        GFB1L-63NHB25300
GFB1L-63NHB25500

GFB1L-63NHC2510            GFB1L-63NHC2530
GFB1L-63NHC25100          GFB1L-63NHC25300
GFB1L-63NHC25500

32A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB3210          GFB1L-63NHB3230
GFB1L-63NHB32100        GFB1L-63NHB32300
GFB1L-63NHB32500

GFB1L-63NHC3210           GFB1L-63NHC3230
GFB1L-63NHC32100         GFB1L-63NHC32300
GFB1L-63NHC32500

40A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB4010          GFB1L-63NHB4030
GFB1L-63NHB40100        GFB1L-63NHB40300
GFB1L-63NHB40500

GFB1L-63NHC4010           GFB1L-63NHC4030
GFB1L-63NHC40100         GFB1L-63NHC40300
GFB1L-63NHC40500

50A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB5010          GFB1L-63NHB5030
GFB1L-63NHB50100        GFB1L-63NHB50300
GFB1L-63NHB50500

GFB1L-63NHC5010           GFB1L-63NHC5030
GFB1L-63NHC50100         GFB1L-63NHC50300
GFB1L-63NHC50500

63A10mA、30mA、100mA、300mA、500mA

GFB1L-63NHB6310          GFB1L-63NHB6330
GFB1L-63NHB63100        GFB1L-63NHB63300
GFB1L-63NHB63500

GFB1L-63NHC6310           GFB1L-63NHC6330
GFB1L-63NHC63100         GFB1L-63NHC63300
GFB1L-63NHC63500

 

Connecting Line

Rated current In (A)

Nominal cross-sectional area S (mm²) of copper wire

6、10

1-2.5

16

2.5-4

20、25

4-6

32、40

6-10

50、63

10-16

 

Appearance and Installation Dimensions                                            Characteristic Curves         

  

Keywords:

Related Products

undefined

undefined

Welcome your message consultation

You can also submit information online, and we will reply to you within 24 hours!

Sales support

Yueqing Good Future Electrical Co.,Ltd.

Phone: +86  138  0686  5401 

Tel: +86  577  6161  6165 

Email : gf@gf-ele.com

No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town

Yueqing City,Wenzhou City,Zhejiang Province,China

 

Certificate

图片名称
图片名称

Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.

安安新材料

Business license

Get in touch

Provide comprehensive technical support and maintenance services to respond to your needs in a timely manner.