GFB1L-63N Electronic Residual Current Circuit Breaker (3P+N Longbody) RCBO

GFB1L-63N Residual Current Breaker RCBO 6kA 3 Pole and Neutral 63A C Curve 30mA Type A (Longbody)sidual Current Breaker RCBO 6kA 3 Pole and Neutral 63A C Curve 30mA Type A (Longbody)
GFB1L-63N Range of residual current devices (RCDs) are a high-performance electrical safety solution designed for commercial, industrial and mining applications. These RCDs offer a high level of selectivity, with sensitives including 10mA, 30mA, 100mA,300mA and500mA, types starting at Type A for general purpose applications through to Type F and B for more complex loads.
● Standard: IEC/EN 61009-1
● Type: AC, A
● Rated current: 6A,10A,16A,20A,25A,32A,40A,50A,63A
● Rated voltage: 400/415V~
● Number of poles: 3P+N
● Rated Residual Operating Current (I△n): 10mA, 30mA, 100mA, 300mA,500mA
● Rated short-circuit breaking capacity: 6kA
● Tripping curve: B,C
● Ambient air temperature: -35℃~+70 ºC
● Certificates: CB,CE, UKCA,SEMKO

Product Description

Model and Meaning                             ●Introduction

GFB1L-63N Electronic residual current trip (3P+N) is a low-voltage protection device that integrates overload, short circuit, and leakage protection. Its core feature is the use of electronic trip technology to achieve accurate leakage detection. The following is the key description:
 

 

 

Ⓐ structural property
● Polarity configuration: 3P+N denotes a three-phase (L1/L2/L3) system with a neutral (N) line. The neutral pole is typically used solely for isolation or leakage detection, without overcurrent protection capability.
● Module design: The standard module is 54mm (3×18mm), with the N pole occupying space but not independently separated.
Ⓑ principle of work and power
● Leakage protection: Detects residual current through a zero-sequence current transformer. When the leakage current exceeds the preset threshold (e.g., 30mA), the electronic tripping mechanism activates.
● Wiring requirements: Strictly follow the left neutral, right live principle. The N line must be connected to the terminal marked N. Otherwise, the protection may fail.
Ⓒ application scenarios-Industrial control systems, electrical installations in commercial buildings, and household circuit protection
● Suitable for three-phase four-wire systems (e.g., 380V power equipment) where neutral line leakage detection is required but no neutral line disconnection is needed.
● Common in industrial control, commercial building distribution boxes, etc.
Ⓓ Selection considerations
● Specify the N-pole function requirements (e.g., whether synchronization and disconnection are required)
● Prioritize products compliant with IEC/EN 61009-1 standards, ensuring a breaking capacity of ≥6kA

Technical Parameters

Product Model

GFB1L-63N

Product complies with standard

IEC/EN 61009-1

No. of poles

3P+N

Rated current (In)

6A,10A,16A,20A,25A,32A,40A,50A,63A

Rated sensitivity currents I△n

10mA, 30mA, 100mA, 300mA,500mA

Rated short-circuit breaking capacity

6kA

Energy limiting class

3

Rated voltage (Ue)

400/415V  

Rated impulse withstand voltage (1.2/50) Uimp

4kV

Trip curve

B、C

Leakage current type 

AC、A

Tripping time

300ms

Min.service voltage

207V

Max.operating voltage(Uamx)

457V

Protected neutral pole

No

Isolator application

Yes

Disconnection characteristic

Undelayed

Protection

Ground fault, Overcurrent and short circuit

Type of trip

Ground fault: Electronic

Overload and short circuit: Thermo-magnetic

Residual current off-time under I△n

≤0.1s

Reted residual making and breaking capacity (I△m)

500A(In≤50A)

Thermal release characteristic

(1.13-1.45) x In

Magnetic release characteristic

B:(3-5) x In, C:(5-10) x In

Electrical Life

10000 Cycles

Mechanical Life

20000 Cycles

Contact Position Indicator

Yes, ON (red); OFF (green)

Ambient Temperature

-35℃~+70℃, Maximum Humidity 95%

Datum temperature

30℃

Protection Degree

IP20

Connectable conductor cross section solid-core

1-25mm²

Connectable conductor cross section multi-wired

1-16mm²

Torque (N·m)

-35℃~+70℃, Maximum Humidity 95%

Installation

30℃

Depth

IP20

Height

1-25mm²

Width

1-16mm²

Product Types Choosing

Rated CurrentRated Residual Operation Current(I△n)Product Number
Type  BType  C
6A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB0610          GFB1L-63NB0630
GFB1L-63NB06100        GFB1L-63NB06300
GFB1L-63NB06500

GFB1L-63NC0610            GFB1L-63NC0630
GFB1L-63NC06100          GFB1L-63NC06300
GFB1L-63NC06500

10A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB1010          GFB1L-63NB1030
GFB1L-63NB10100        GFB1L-63NB10300
GFB1L-63NB10500

GFB1L-63NC1010            GFB1L-63NC1030
GFB1L-63NC10100          GFB1L-63NC10300
GFB1L-63NC10500

16A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB1610          GFB1L-63NB1630
GFB1L-63NB16100        GFB1L-63NB16300
GFB1L-63NB16500

GFB1L-63NC1610            GFB1L-63NC1630
GFB1L-63NC16100          GFB1L-63NC16300
GFB1L-63NC16500

20A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB2010          GFB1L-63NB2030
GFB1L-63NB20100        GFB1L-63NB20300
GFB1L-63NB20500

GFB1L-63NC2010            GFB1L-63NC2030
GFB1L-63NC20100          GFB1L-63NC20300
GFB1L-63NC20500

25A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB2510          GFB1L-63NB2530
GFB1L-63NB25100        GFB1L-63NB25300
GFB1L-63NB25500

GFB1L-63NC2510            GFB1L-63NC2530
GFB1L-63NC25100          GFB1L-63NC25300
GFB1L-63NC25500

32A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB3210          GFB1L-63NB3230
GFB1L-63NB32100        GFB1L-63NB32300
GFB1L-63NB32500

GFB1L-63NC3210           GFB1L-63NC3230
GFB1L-63NC32100         GFB1L-63NC32300
GFB1L-63NC32500

40A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB4010          GFB1L-63NB4030
GFB1L-63NB40100        GFB1L-63NB40300
GFB1L-63NB40500

GFB1L-63NC4010           GFB1L-63NC4030
GFB1L-63NC40100         GFB1L-63NC40300
GFB1L-63NC40500

50A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB5010          GFB1L-63NB5030
GFB1L-63NB50100        GFB1L-63NB50300
GFB1L-63NB50500

GFB1L-63NC5010           GFB1L-63NC5030
GFB1L-63NC50100         GFB1L-63NC50300
GFB1L-63NC50500

63A10mA、30mA、100mA、300mA、500mA

GFB1L-63NB6310          GFB1L-63NB6330
GFB1L-63NB63100        GFB1L-63NB63300
GFB1L-63NB63500

GFB1L-63NC6310           GFB1L-63NC6330
GFB1L-63NC63100         GFB1L-63NC63300
GFB1L-63NC63500

 

Connecting Line

Rated current In (A)

Nominal cross-sectional area S (mm²) of copper wire

6、10

1-2.5

16

2.5-4

20、25

4-6

32、40

6-10

50、63

10-16

 

Appearance and Installation Dimensions                                            Characteristic Curves         

  

Keywords:

Related Products

undefined

undefined

Welcome your message consultation

You can also submit information online, and we will reply to you within 24 hours!

Sales support

Yueqing Good Future Electrical Co.,Ltd.

Phone: +86  138  0686  5401 

Tel: +86  577  6161  6165 

Email : gf@gf-ele.com

No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town

Yueqing City,Wenzhou City,Zhejiang Province,China

 

Certificate

图片名称
图片名称

Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.

安安新材料

Business license

Get in touch

Provide comprehensive technical support and maintenance services to respond to your needs in a timely manner.