GFU1-Ⅰ+Ⅱ AC Surge Protective Device
The GFU1-Ⅰ+Ⅱ AC Surge protective device is designed for AC power systems operating at 50/60Hz with rated voltages of 230V single-phase or 400V three-phase. It complies with IEC 61643-11 standards, meeting both Class I and II surge protection requirements. This device suppresses transient overvoltages below equipment surge withstand limits while dissipating surge energy to protect electrical circuits and equipment. Key features include: L-PE, N-PE, and L-N protection modes compatible with various grid systems; aging and overheat protection with degradation indicators; plug-in design; and optional remote alarm functionality. AC Surge Protection Device (SPD) - Reliable Power Protection Solution。
● Core applications:Lightning protection and surge protection for incoming line cabinets.
● Certification:IEC 61643-11.
● Kind of test:Type1+2/ClassⅠ+Ⅱ
● Number of poles:1:1P,2:2P,3:3P,4:4P,1PN:1P+NPE,3PN:3P+NPE
● Dash current:7:7kA,12:12.5kA
● Maximum continuous operating voltage(N-PE)(Uc):255V
● Working voltage:150:150V;275:275V;320:320V;385:385V;440:440V
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
Product Description
●Introduction ●Model and Meaning
Our AC Surge Protection Device is designed to safeguard electrical equipment from transient voltage spikes and surges in AC power systems. This high-performance SPD provides robust protection for residential, commercial, and industrial applications.
Ⓐ Key Features
● Advanced Protection Technology: Utilizes high-quality metal oxide varistors (MOVs) for fast response to voltage transients (<25ns response time)
● Wide Voltage Range: Available for various AC systems (120V, 230V, 400V, etc.)
● High Surge Capacity: Withstands surge currents up to 80kA (8/20μs waveform)
● Multi-Stage Protection: Incorporates coordinated multi-level protection for optimal equipment safety
● Thermal Protection: Built-in thermal disconnect mechanism for fail-safe operation
● Compact Design: Space-saving modular design for easy installation in distribution panels
Ⓑ Applications:
Main service entrance protection,Sub-panel protection,Critical equipment protection (servers, medical equipment, etc.)
Industrial control systems,HVAC and elevator systems。
Ⓒ Why Choose Our SPD?
Superior surge protection performance,Enhanced equipment lifespan,Reduced downtime and maintenance costs,Comprehensive warranty support,Global safety certifications,For detailed technical documentation or custom solutions, please contact our technical support team。
●Technical parameters
Core applications | Lightning protection and surge protection for incoming line cabinets | ||||||||
Number of poles | 1P | 2P | 3P | 4P | 1P+NPE | 3P+NPE | |||
Applicable power system | TN-S、TN、TT | TN-S | TN-C | TN-S | TT、TN-S | ||||
Protected mode | L-PE、L-N | L-PE、N-PE | L-PE | L-PE、N-PE | L-N、N-PE | ||||
Kind of test | Type1+2/ClassⅠ+Ⅱ | ||||||||
Product model | GFU1-Ⅰ+Ⅱ-7 | GFU1-Ⅰ+Ⅱ-12 | |||||||
Maximum continuous operating voltage (L-N) (Uc) | 150V | 275V | 320V | 385V | 400V | 150V | 275V | 320V | 385V |
Maximum continuous operating voltage (N-PE) (Uc) | 255V | 255V | |||||||
Impulse current (10/350μs) (Iimp) | 7kA | 12.5kA | |||||||
Nominal discharge current (8/20μs) (In) | 20kA | 30kA | |||||||
Maximum discharge current (8/20μs) (Imax) | 50kA | 60kA | |||||||
Voltage protection level(L-N)/(N-PE)(Up) | 1.2/1.5kV | 1.4/1.5kV | 1.6/1.5kV | 1.8/1.5kV | 1.8/1.5kV | 1.2/1.5kV | 1.4/1.5kV | 1.6/1.5kV | 1.8/1.5kV |
Maximum Reserve Fuse(gL/gG) | 125A | 125A | |||||||
Response time(L-N)/(N-PE)(tA) | ≤25ns/≤100ns | ||||||||
Operating Temperature Range | -35 ºC -+70 ºC | ||||||||
Work Status / Fault Indication | Green/red | ||||||||
Remote signaling terminal wiring capability | Maximum 4-35mm² | ||||||||
Tightening torque | 2-3.5N·m | ||||||||
levels of protection | IP20 | ||||||||
Terminal wiring capability | Hard wire2.5-35mm² ,soft wire2.5-25mm² | ||||||||
Installation | Mounting on 35mm DIN rail | ||||||||
●Product Types Choosing
| Impulse Current (10/350μs) (Iimp) | working voltage (L-N) (Uc) | Number of poles | |||||
| 1P | 2P | 3P | 4P | 1P+NPE | 3P+NPE | ||
| 7kA | 150V | GFU1-Ⅰ+Ⅱ-7-1501S | GFU1-Ⅰ+Ⅱ-7-1502S | GFU1-Ⅰ+Ⅱ-7-1503S | GFU1-Ⅰ+Ⅱ-7-1504S | GFU1-Ⅰ+Ⅱ-7-1501NPES | GFU1-Ⅰ+Ⅱ-7-1503NPES |
| 275V | GFU1-Ⅰ+Ⅱ-7-2751S | GFU1-Ⅰ+Ⅱ-7-2752S | GFU1-Ⅰ+Ⅱ-7-2753S | GFU1-Ⅰ+Ⅱ-7-2754S | GFU1-Ⅰ+Ⅱ-7-2751NPES | GFU1-Ⅰ+Ⅱ-7-2753NPES | |
| 320V | GFU1-Ⅰ+Ⅱ-7-3201S | GFU1-Ⅰ+Ⅱ-7-3202S | GFU1-Ⅰ+Ⅱ-7-3203S | GFU1-Ⅰ+Ⅱ-7-3204S | GFU1-Ⅰ+Ⅱ-7-3201NPES | GFU1-Ⅰ+Ⅱ-7-3203NPES | |
| 385V | GFU1-Ⅰ+Ⅱ-7-3851S | GFU1-Ⅰ+Ⅱ-7-3852S | GFU1-Ⅰ+Ⅱ-7-3853S | GFU1-Ⅰ+Ⅱ-7-3854S | GFU1-Ⅰ+Ⅱ-7-3851NPES | GFU1-Ⅰ+Ⅱ-7-3853NPES | |
| 400V | GFU1-Ⅰ+Ⅱ-7-4001S | GFU1-Ⅰ+Ⅱ-7-4002S | GFU1-Ⅰ+Ⅱ-7-4003S | GFU1-Ⅰ+Ⅱ-7-4004S | GFU1-Ⅰ+Ⅱ-7-4001NPES | GFU1-Ⅰ+Ⅱ-7-4003NPES | |
| 12.5kA | 150V | GFU1-Ⅰ+Ⅱ-12.5-1501S | GFU1-Ⅰ+Ⅱ-12.5-1502S | GFU1-Ⅰ+Ⅱ-12.5-1503S | GFU1-Ⅰ+Ⅱ-12.5-1504S | GFU1-Ⅰ+Ⅱ-12.5-1501NPES | GFU1-Ⅰ+Ⅱ-12.5-1503NPES |
| 275V | GFU1-Ⅰ+Ⅱ-12.5-2751S | GFU1-Ⅰ+Ⅱ-12.5-2752S | GFU1-Ⅰ+Ⅱ-12.5-2753S | GFU1-Ⅰ+Ⅱ-12.5-2754S | GFU1-Ⅰ+Ⅱ-12.5-2751NPES | GFU1-Ⅰ+Ⅱ-12.5-2753NPES | |
| 320V | GFU1-Ⅰ+Ⅱ-12.5-3201S | GFU1-Ⅰ+Ⅱ-12.5-3202S | GFU1-Ⅰ+Ⅱ-12.5-3203S | GFU1-Ⅰ+Ⅱ-12.5-3204S | GFU1-Ⅰ+Ⅱ-12.5-3201NPES | GFU1-Ⅰ+Ⅱ-12.5-3203NPES | |
| 385V | GFU1-Ⅰ+Ⅱ-12.5-3851S | GFU1-Ⅰ+Ⅱ-12.5-3852S | GFU1-Ⅰ+Ⅱ-12.5-3853S | GFU1-Ⅰ+Ⅱ-12.5-3854S | GFU1-Ⅰ+Ⅱ-12.5-3851NPES | GFU1-Ⅰ+Ⅱ-12.5-3853NPES | |
●Circuit Diagram

●Appearance and Installation Dimensions

Keywords:
Related Products
undefined
Welcome your message consultation
You can also submit information online, and we will reply to you within 24 hours!
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town
Yueqing City,Wenzhou City,Zhejiang Province,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.