GFU1-Ⅱ AC Surge Protective Device
The GFU1-Ⅱ AC Surge Protective Device (SPD) is a high-performance overvoltage protection solution designed to safeguard electrical and electronic equipment from transient surges, lightning strikes, and other power disturbances in AC power systems.
● Core applications:Lightning protection and surge protection for incoming line cabinets.
● Certification:IEC 61643-11.
● Kind of test:Type2/ClassⅡ
● Number of poles:1:1P,2:2P,3:3P,4:4P,1PN:1P+NPE,3PN:3P+NPE
● Dash current:7:7kA,12:12.5kA
● Maximum continuous operating voltage(N-PE)(Uc):255V
● Working voltage:150:150V;275:275V;320:320V;385:385V;440:440V
● Operating Temperature Range: -35 ºC to+70 ºC
● Operating state/fault indication:Green/Red
Product Description
●Introduction ●Model and Meaning
Our AC Surge Protection Device is designed to safeguard electrical equipment from transient voltage spikes and surges in AC power systems. This high-performance SPD provides robust protection for residential, commercial, and industrial applications.
GFU1-Ⅱ AC Surge Protective Device (SPD) Designed for AC 50/60Hz power distribution and control systems with single-phase rated voltages, this surge protector (SPD) meets Class II testing standards. It suppresses transient overvoltages below equipment surge withstand limits while dissipating surge energy, thereby protecting system circuits and equipment.
The surge protector features three protection modes: L-PE, N-PE, and L-N, compatible with various power grid systems. It provides aging and overheating protection, includes a degradation indicator, features an insert-type design, and offers optional remote alarm functionality.
Main functions: lightning protection and surge protection for incoming line cabinets
Ⓐ Key Features
● Advanced Protection Technology – Utilizes high-quality metal oxide varistors (MOVs) and multi-stage protection circuits to ensure reliable surge suppression.
● Wide Application Range – Suitable for low-voltage AC power systems in residential, commercial, and industrial settings.
● High Surge Current Capacity – Withstands impulse currents up to 40kA (8/20μs), providing robust defense against severe electrical surges.
● Visual Status Indication – Equipped with an LED indicator for real-time monitoring of operational status (green: normal; red: fault).
● Thermal Protection & Fail-Safe Mechanism – Built-in thermal disconnector automatically cuts off faulty SPDs to prevent overheating and fire hazards.
● Compact & Easy Installation – Modular design allows for DIN rail mounting, ensuring quick and hassle-free integration into distribution panels.
Ⓑ Compliance & Safety Standards
● Meets IEC 61643-11 standards for surge protective devices.
● Certified by authoritative testing institutions for safety and performance.
Ⓒ Applications
Power Distribution Systems – Protects switchboards, meters, and control panels.
Sensitive Electronics – Shields computers, servers, medical equipment, and communication devices.
Industrial & Infrastructure – Ensures stable operation of machinery, HVAC systems, and lighting networks.
Ⓓ Why Choose GFU1-Ⅱ SPD?
✅ Durability – Long service life with stable performance under frequent surges.
✅ Cost-Effective – Reduces downtime and equipment damage, lowering maintenance costs.
✅ Global Reliability – Trusted by engineers worldwide for critical surge protection.
For detailed specifications, installation guidelines, or customization options, please contact our technical team.
Protect Your Power System with GFU1-Ⅱ SPD – Where Safety Meets Innovation!
●Technical parameters
Number of poles | 1P | 2P | 3P | 4P | 1P+NPE | 3P+NPE |
Applicable power system | TN-S、TN、TT | TN-S | TN-C | TN-S | TT、TN-S | |
Protected mode | L-PE、L-N | L-PE、N-PE | L-PE | L-PE、N-PE | L-N、N-PE | |
Kind of test | Type2/ClassⅡ | |||||
Product model | GFU1-Ⅱ-40 | |||||
Maximum continuous operating voltage (L-N) (Uc) | 150V | 275V | 320V | 385V | 400V | |
Maximum continuous operating voltage (N-PE) (Uc) | 255V | |||||
Nominal discharge current (8/20μs) (In) | 20kA | |||||
Maximum discharge current (8/20μs) (Imax) | 40kA | |||||
Voltage protection level(L-N)/(N-PE)(Up) | 1.2/1.5kV | 1.5/1.5kV | 1.6/1.5kV | 1.8/1.5kV | 1.8/1.5kV | |
Maximum Reserve Fuse(gL/gG) | 125A | |||||
Response time(L-N)/(N-PE)(tA) | ≤25ns/≤100ns | |||||
Operating Temperature Range | -35 ºC -+70 ºC | |||||
Work Status / Fault Indication | Green/red | |||||
Remote signaling terminal wiring capability | Maximum 4-35mm² | |||||
Tightening torque | 2-3.5N·m | |||||
levels of protection | IP20 | |||||
Terminal wiring capability | Hard wire2.5-35mm² ,soft wire2.5-25mm² | |||||
Installation | Mounting on 35mm DIN rail | |||||
●Product Types Choosing
| Impulse Current (10/350μs) (Iimp) | working voltage (L-N) (Uc) | Number of poles | |||||
| 1P | 2P | 3P | 4P | 1P+NPE | 3P+NPE | ||
| 40kA | 150V | GFU1-Ⅱ-40-1501S | GFU1-Ⅱ-40-1502S | GFU1-Ⅱ-40-1503S | GFU1-Ⅱ-40-1504S | GFU1-Ⅱ-40-1501NPES | GFU1-Ⅱ-40-1503NPES |
| 275V | GFU1-Ⅱ-40-2751S | GFU1-Ⅱ-40-2752S | GFU1-Ⅱ-40-2753S | GFU1-Ⅱ-40-2754S | GFU1-Ⅱ-40-2751NPES | GFU1-Ⅱ-40-2753NPES | |
| 320V | GFU1-Ⅱ-40-3201S | GFU1-Ⅱ-40-3202S | GFU1-Ⅱ-40-3203S | GFU1-Ⅱ-40-3204S | GFU1-Ⅱ-40-3201NPES | GFU1-Ⅱ-40-3203NPES | |
| 385V | GFU1-Ⅱ-40-3851S | GFU1-Ⅱ-40-3852S | GFU1-Ⅱ-40-3853S | GFU1-Ⅱ-40-3854S | GFU1-Ⅱ-40-3851NPES | GFU1-Ⅱ-40-3853NPES | |
| 400V | GFU1-Ⅱ-40-4001S | GFU1-Ⅱ-40-4002S | GFU1-Ⅱ-40-4003S | GFU1-Ⅱ-40-4004S | GFU1-Ⅱ-40-4001NPES | GFU1-Ⅱ-40-4003NPES | |
●Circuit Diagram

●Appearance and Installation Dimensions

Keywords:
Related Products
undefined
Welcome your message consultation
You can also submit information online, and we will reply to you within 24 hours!
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
No.136-138,Xinguang Avenue,Xinguang lndustrial Zone,Liushi Town
Yueqing City,Wenzhou City,Zhejiang Province,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.