Miniature Circuit Breaker
undefined
GFB1-125Z DC circuit breaker is used in lines with rated voltage up to 1000V and rated current up to 63A for overload and short circuit protection, and can also be used as infrequent operation conversion of the line。
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 250/500V/750V/1000V
● Number of poles: 1P,2P,3P,4P
● Rated short-circuit breaking capacity: 6kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 250/500V/750V/1000V
● Number of poles: 1P,2P,3P,4P
● Rated short-circuit breaking capacity: 6kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
GFB1-125ZH DC circuit breaker is used in lines with rated voltage up to 1000V and rated current up to 63A for overload and short circuit protection, and can also be used as infrequent operation conversion of the line。
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 250/500V/750V/1000V
● Number of poles: 1P,2P,3P,4P
● Rated short-circuit breaking capacity: 10kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 250/500V/750V/1000V
● Number of poles: 1P,2P,3P,4P
● Rated short-circuit breaking capacity: 10kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
GFB1-125ZG DC circuit breaker is used in lines with rated voltage up to 2000V and rated current up to 63A for overload and short circuit protection, and can also be used as infrequent operation conversion of the line。
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 500/1000V/1500V/2000V
● Number of poles: 1P,2P,3P,4P
● Rated Breaking Capacity: 1.5kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 500/1000V/1500V/2000V
● Number of poles: 1P,2P,3P,4P
● Rated Breaking Capacity: 1.5kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
GFB1-125ZGH DC circuit breaker
GFB1-125ZGH DC circuit breaker is used in lines with rated voltage up to 2000V and rated current up to 63A for overload and short circuit protection, and can also be used as infrequent operation conversion of the line。
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 500/1000V/1500V/2000V
● Number of poles: 1P,2P,3P,4P
● Rated Breaking Capacity: 3kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
● Standard: IEC/EN60947-2
●Tripping Mode:Thermal-Magnetic Tripping
● Rated current: 1A~63A
● Rated voltage: 500/1000V/1500V/2000V
● Number of poles: 1P,2P,3P,4P
● Rated Breaking Capacity: 3kA
● Ambient air temperature: -35℃~+70℃
● Connection: From top and bottom
● Certificates: CB, CE, UKCA,SEMKO
Product Categories
No data
Product Categories
Sales support
Yueqing Good Future Electrical Co.,Ltd.
Phone: +86 138 0686 5401
Tel: +86 577 6161 6165
Email : gf@gf-ele.com
Whatsapp:+86-19511298526
No.136-138,Xinguang Avenue,Xinguang lndustrial
Zone,Liushi,Yueqing,Wenzhou,Zhejiang,China
Certificate
Copyright © 2024 Yueqing Good Future Electrical Co., Ltd.